Product overview: Fluke 317 Clamp Meters

The Fluke 317 and 319 are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments. The Fluke 317and 319 also offer AC/DC current measurements and has a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, the Fluke 319 also equip with In-rush current and Frequency functions for testing motors, lighting, etc.

 

 

 

Product overview: Fluke 317 Clamp Meters

The Fluke 317 and 319 are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments. The Fluke 317and 319 also offer AC/DC current measurements and has a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, the Fluke 319 also equip with In-rush current and Frequency functions for testing motors, lighting, etc.

 

 

 

 

 

 

317 Electrical specifications
Current AC Range 40.00 A, 600.0 A

 

Resolution 0.01 A, 0.1 A

 

Accuracy 1.6% ±6 digit (50-60 Hz) {40 A}

 

 

2.5% ±8 digit (60-500 Hz) {40 A}

 

 

1.5% ±5 digit (50-60 Hz) {600 A}

 

 

2.5% ±5 digit (60-500 Hz) {600 A}

 

Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A

 

AC response rms
Current DC Range 40.00 A, 600.0 A

 

Resolution 0.01 A, 0.1 A

 

Accuracy 1.6% ±6 digit (40 A)

 

 

1.5% ±5 digit (600 A)
Voltage AC Range 600.0 V

 

Resolution 0.1 V

 

Accuracy 1.5% ±5 digit (20-500Hz)

 

AC response rms
Voltage DC Range 600.0 V

 

Resolution 0.1 V

 

Accuracy 1% ±4 digit
Resistance Range 400.0 Ω, 4000 Ω

 

Resolution 0.1 Ω, 1 Ω

 

Accuracy 1% ±5 digit

 

Continuity ≤ 30 Ω
Inrush Integration time N/A
Frequency Range N/A

 

Accuracy N/A

 

Trigger Level N/A

 

Environmental specifications
Operating temperature 14°F to 122°F (-10 °C to 50 °C)
Storage temperature -40 °F to 140 °F (-40 °C to 60 °C)
Operating humidity Non-condensing (< 50 °F) (< 10 °C)

 

90% RH (50 °F to 86 °F) (10 °C to 30 °C)

 

75% RH (86 °F to 104 °F) (30 °C to 40 °C)

 

45% RH (104 °F to 122 °F) (40 °C to 50 °C)

 

(Without condensation)
Operating altitude 1 mile (2000 meters) above mean sea level
Storage altitude 7 miles (12,000 meters) above mean sea level
IP Rating IP40
Vibration requirements Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop test requirements 3 ft (1 m) drop test, six sides, oak floor
EMI, RFI, EMC Instrument unspecified for use in EMC field ≥ 0.1 V/m
Temperature coefficients 0.1x (specified accuracy)/ °C

 

(<64 °F or > 82° F)

 

(<18 °C or > 28 °C)

 

 